Necessary conditions for 24kw PTC heater

The heater is mainly used for heating the passenger compartment ,defrosting and removing fog on the window,or preheating battery thermal management system battery ,to meet the corresponding regulations, functional requirements.
Necessary conditions for heater:
(1)The heater is controlled by CAN communication
(2)High voltage power supply
(3)Low voltage power supply (BATT) or Kl15 (ignition switch voltage), Kl31 (GND)
(4)The heater needs to set a high voltage interlock circuit
(5)The vehicle must be equipped with an insulation monitoring device to monitor:
a: Over (under) voltage protection
b: Short circuit protection (current-limiting fuse in distribution box)
c: Leakage protection
d: Interlock response
(6)High voltage electric heater must be equipped with 80A current-limiting fuse
(7)It must be ensured that the high voltage power supply has no reverse polarity
(8)The vehicle needs to be powered off when overvoltage occurs
(9)High voltage input should be precharged
(10)The high voltage input should be equipped with a relay, when a serious fault occurs, the high voltage can be cut off without affecting the safety of the whole vehicle.
PTC Safe Working Scope
The heater uses a low TC(215°C) PTC element, which limits the maximum temperature that the system can reach (without control circuits), which is within the temperature range that the surrounding components can withstand (even under the worst conditions).