Latest Products

  • 20kw Electric PTC Heater
  • 2.5kw High Voltage Coolant Heater
  • 5KW High Voltage Coolant PTC Heater
  • Electric Bus Defroster
  • 12v Diesel Water Heater
  • 2kw Air Parking Heater

Contact Us

    Hebei Nanfeng Automobile Equipment (Group) Co.,Ltd

    Phone: +86 18811334770

    Tel: +86 0317 8620396

    Tel: +86 010 58673556

    Candy Jiao

    E-mail: nh.jiao@auto-parkingheater.com

    Email: nh.li@auto-parkingheater.com

    Add: Room 505, Building B, Free Town Center, No.58, East Third Ring South Road, Chaoyang District, Beijing, 100022, P.R.China

24V Fan-Cooled Coolant Pump 500-800W video

24V Fan-Cooled Coolant Pump 500-800W

Compare NF Group 500W, 600W, 700W and 800W fan-cooled 24V coolant pumps: flow, head, current, D38 ports and dimensions. Find the right model for your battery, cabin or power-electronics loop.

Description

If you're looking for the 24v fan-cooled coolant pump 500-800w, welcome to wholesale the product from our factory. As one of the leading manufacturers and suppliers in China, we will offer you the best service and fast delivery. Now, check the quotation with our seller.

 

24V Fan-Cooled Coolant Pumps: 500W to 800W

One BLT 4846 platform, four power steps. Compare the 500W, 600W, 700W and 800W fan-cooled 24V coolant pumps by flow, head, current draw and envelope, then choose the right point for your battery, cabin or power-electronics loop. All four share D38 ports, a brushless canned motor and an integrated cooling fan.

Four Power Steps, One Platform

Model Power Rated current Max flow Max head L × W × H Port
BLT4846-24V-500W-D38 500 W 21 A 7700 L/h 39 m 252 × 115 × 147 mm D38
BLT4846-24V-600W-D38 600 W 25 A 7850 L/h 40 m 252 × 115 × 147 mm D38
BLT4846-24V-700W-D38 700 W 29.5 A 8400 L/h 41 m 252 × 136 × 147 mm D38
BLT4846-24V-800W-D38 800 W 33.4 A 8500 L/h 49 m 252 × 136 × 147 mm D38

Series comparison figures are from the 2024 BLT electronic water pump catalogue. The dedicated NF GROUP V1.5 specification for the 600W part states 3.7 ± 0.1 bar, 7600 ± 10% L/h and 245 × 115 × 147 mm. Use the part-level specification for quotation and drawing; use the table above only to compare the range.

BLT 4846 series fan cooled electronic water pump brochure with specifications

How to Read Flow and Head

Flow tells you how much coolant the pump can move; head tells you how hard it can push against restriction. A long run of narrow hose, a dense radiator core and several valves all consume head. Pick the pump whose curve still crosses your required flow at the real system resistance - not the one with the largest free-flow number.

System What usually drives the choice Starting point
Battery pack preheating Moderate flow, tight packaging 500W
Bus cabin + battery loop Higher flow, frequent low-speed operation 600W fan-cooled
Dual loop or fast-charge cooling Flow and continuous duty both matter 700W fan-cooled
Long pipe runs / high restriction Head is the limiting factor 800W fan-cooled

In every case the fan matters for the same reason: it keeps the motor and driver from heating up while the coolant loop is working hard. The advantage grows with power, because a 700W or 800W pump dissipates more heat inside the same compact housing.

800W class fan cooled pump shown at an angle

Higher-power fan cooled pump body

Top view of the fan cooled coolant pump

Mounting fins and outlet orientation

What Stays the Same Across the Range

  • Rated 24 V DC with DC18–35 V operating window.
  • D38 inlet and outlet for a common hose and coupling choice.
  • Brushless DC canned motor: no brushes to wear, no rotating shaft seal to leak.
  • IP67 protection and aluminium alloy housing.
  • PWM speed control with fault output; no-signal fallback to maximum speed.
  • Split mounting bracket with 4 × M5/M6 holes, customisable to the vehicle.

Why Fan Cooling Scales With Power

A pump converts electrical power into hydraulic power, and the difference becomes heat inside the motor and electronics. At 500W that heat is manageable with a large aluminium surface; at 800W in a similar envelope, natural convection is not enough during continuous operation. The axial fan moves air across the fins so the higher-power models can hold their speed instead of derating. It needs no separate power or control line - it turns whenever the pump turns.

Ordering Checklist

  • Working voltage and worst-case supply dip.
  • Required flow at your actual pressure drop, not at zero restriction.
  • Coolant type, concentration and maximum temperature.
  • Available space around the pump, including airflow clearance at the fan end.
  • Port orientation and bracket hole pattern.
  • Control preference: PWM with fault line, or CAN on request.

FAQ

Can I swap a 500W pump for an 800W one in the same pipes?

Only after checking the curve. Higher head can push more flow through the same restriction, which may exceed hose or heat-exchanger design limits.

Are all four models fan cooled?

The 4846 series shown here shares the fan-cooled motor platform. Confirm the exact part number when ordering.

Do the 700W and 800W pumps use the same bracket?

The 500/600W versions are 252 × 115 × 147 mm and the 700/800W versions 252 × 136 × 147 mm in the catalogue; the bracket hole pattern is 100 × 50.2 mm with 4-M5/M6 holes. Confirm against the drawing.

What is the benefit over a non-fan pump of the same wattage?

Better sustained performance in hot, low-airflow installations. See the 600W fan-cooled product page for the thermal explanation.

Can you mix pump power levels in one vehicle?

Yes, common in dual-loop architectures. Tell us the loop layout and we will propose a combination.

Tell us your duty point and installation envelope. We will send the curve, drawing and quotation for the 500W, 600W, 700W or 800W fan-cooled pump that fits - not simply the largest one.

Contact now

Hot Tags: 24v fan-cooled coolant pump 500-800w, China, factory, suppliers, manufacturers, seller, wholesale, quotation

Send Inquiry

(0/10)

clearall