Latest Products

  • 20kw Electric PTC Heater
  • 2.5kw High Voltage Coolant Heater
  • 5KW High Voltage Coolant PTC Heater
  • Electric Bus Defroster
  • 12v Diesel Water Heater
  • 2kw Air Parking Heater

Contact Us

    Hebei Nanfeng Automobile Equipment (Group) Co.,Ltd

    Phone: +86 18811334770

    Tel: +86 0317 8620396

    Tel: +86 010 58673556

    Candy Jiao

    E-mail: nh.jiao@auto-parkingheater.com

    Email: nh.li@auto-parkingheater.com

    Add: Room 505, Building B, Free Town Center, No.58, East Third Ring South Road, Chaoyang District, Beijing, 100022, P.R.China

600W Fan-Cooled Electronic Water Pump video

600W Fan-Cooled Electronic Water Pump

NF Group 600W 24V fan-cooled brushless coolant pump for EV buses and trucks. 7600 L/h, 3.7 bar, PWM speed control, IP67, no-load protection. The integrated fan keeps the motor cool at low speed. Request a quote.

Description

If you're looking for the 600w fan-cooled electronic water pump, welcome to wholesale the product from our factory. As one of the leading manufacturers and suppliers in China, we will offer you the best service and fast delivery. Now, check the quotation with our seller.

 

600W Fan-Cooled Electronic Water Pump for EV Cooling

A 24V brushless coolant pump with an integrated axial fan on the motor end. Built for electric buses, trucks and battery thermal loops: 600W, DC18–35V, 7600 L/h opening flow, 3.7 bar maximum pressure, IP67 and PWM speed control. The fan is not decorative - it removes heat from the pump motor and driver electronics when the coolant is already hot and the vehicle is barely moving.

What the Fan Actually Does

Look at the rear of the pump and you will see an axial fan behind a metal guard, mounted directly on the motor end. It drives air across the cast-aluminium fins around the motor housing. The coolant flowing through the pump is already carrying heat away from the battery, PTC heater or power electronics, so it cannot also be relied on to cool the pump itself. The fan gives the motor and the integrated drive board their own heat path: forced air, independent of coolant temperature.

This is the difference between this model and a standard canned motor pump of the same power. Both move coolant; only one actively manages its own thermal load. In stop-and-go bus service, at truck idle, or during stationary charging, there is almost no ram air through the engine bay - the fan is doing the work that vehicle motion would otherwise do.

600W water pump fan close-up with metal protective grille

Rear-mounted axial fan and metal guard

Front view of the 600W fan cooled electronic water pump

D38 inlet and outlet, compact motor body

Full Technical Specification

Item Specification
Model BLT484654-24V-600W-D38 (NF GROUP, V1.5)
Rated voltage 24 V DC
Operating voltage range DC18 V – 35 V
Rated power 600 W
Rated current 25 A
Maximum pressure 3.7 ± 0.1 bar
Opening flow 7600 ± 10% L/h
Fuse specification 60 A or above
Dimensions (L × W × H) 245 × 115 × 147 mm
Inlet / outlet diameter D38 mm
Protection rating IP67
Noise ≤ 70 dB(A)
Working principle Brushless DC canned motor pump
Housing Aluminium alloy, shielded pump drive
Medium temperature -40 °C to 70 °C
Ambient temperature -40 °C to 60 °C
Static storage temperature -40 °C to 105 °C
Service life 10,000 hours
PWM frequency 50–1000 Hz; 200 Hz recommended
PWM duty cycle 0–10% stop; 10–90% linear speed; 90–100% maximum speed
PWM signal No signal detected → automatic maximum speed; input impedance 10 kΩ
Fault output High level = normal; low level (<1 V) = fault
No-load protection Current below 3.2 A for 20 s → shutdown; manual restart required
Connector Yazaki 7282-8497-90 (pump end)

Values above follow the NF GROUP V1.5 specification. The 2024 BLT series catalogue lists 7850 L/h / 40 m for the 600W model; confirm which document applies to your part number before ordering. CAN-based speed control is available on request; the standard harness uses PWM and a fault line.

Flow, Head and Speed Control

The flow–pressure curve slopes down as system resistance rises: the quoted 3.7 bar is the shut-off point, and 7600 L/h is the opening-flow figure measured at 20 °C ambient. In a real vehicle loop, hose diameter, radiator restriction and valve position decide where the pump sits on that curve. Size the pump for the duty point, not for the biggest number on the datasheet.

A PWM signal gives the vehicle controller direct authority over pump speed. Duty below 10% commands stop; between 10% and 90% speed scales linearly; above 90% the pump runs at maximum. If the PWM wire is disconnected, the pump falls back to full speed rather than stopping - a deliberate fail-safe for thermal protection. The yellow wire reports fault status: high means healthy, below 1 V means the controller should investigate.

Where the Built-In Fan Earns Its Place

  • Stop-and-go city buses: frequent stops mean low airflow through the chassis; the fan keeps the motor cool while the cabin and battery loops keep circulating.
  • Idling trucks and refrigeration units: the coolant is hot, the vehicle is stationary, and the pump still has to run - exactly the condition natural convection handles badly.
  • Stationary charging and energy storage: thermal management continues after the vehicle stops; there is no road speed to help.
  • Compact installations: when the pump sits close to a PTC heater or under a fairing, radiated heat adds to the load; forced air gives useful margin.

Side view of fan cooled 24V coolant pump

Aluminium fins and D38 ports

Rear fan view of the 600W electronic water pump

Fan, guard and motor housing

Application Range

Designed for electric buses, city transit buses, electric heavy trucks, sanitation vehicles and hybrid commercial vehicles. Typical circuits include battery pack preheating and cooling, water-based PTC heater loops, drive motor and inverter cooling, DC-DC and on-board charger cooling, plus thermal management for energy storage compartments. Related components in the same loop: our 24kW high voltage coolant heater and electronic water pump series.

Electric buses, trucks and commercial vehicles using NF Group electronic coolant pumps

Installation and Wiring

Wire Function
Red Power supply positive (DC24 V)
Black Ground
White PWM speed control signal input
Yellow Fault signal output
  • Mount the pump below the centre of the water tank so it starts without air locking.
  • The outlet angle shown in the drawing is optimal; the pump head itself can be installed through 360 degrees.
  • Use 4 × M5 or M6 fixing screws; length = mounting plate thickness + 15 mm. The split bracket can be customised.
  • Do not pump liquid containing impurities or magnetic particles smaller than 0.3 mm.
  • The connector is a Yazaki 7282-8497-90; match the mating harness diameter to the pump harness.

Built for Continuous Duty

The brushless motor removes brush wear as a failure mode. The shielded, sealless pump drive eliminates the classic shaft-seal leak path. IP67 sealing, reverse-polarity protection, a wide DC18–35 V window and soft start protect the electrical side; the no-load protection shuts the pump down if current stays under 3.2 A for 20 seconds. Together with the cooling fan, these features support the specified 10,000-hour service life. For the physics behind dry running, see our engineering note on whether an electronic water pump can run dry.

CE certificate of conformity for NF Group electronic pumps

CE conformity document

NF Group factory building

NF Group manufacturing facility

Buyer FAQ

Does the fan cool the coolant?

No. It cools the pump motor and drive electronics. The coolant is heated or cooled by the rest of the thermal loop - PTC heater, radiator, chiller or battery pack. Giving the pump its own airflow prevents the pump from becoming the weak point when the coolant is already warm.

Can I order the same pump without the fan?

Yes. NF Group supplies other 24V electronic coolant pumps in the same series. Tell us your power, flow and installation space and we will confirm whether the fan version or a standard version fits.

What happens if the PWM wire fails?

With no PWM signal detected, the pump automatically runs at maximum speed. The yellow fault line reports internal faults separately.

Why does the datasheet say 3.7 bar but the catalogue says 40 m head?

They are different documents and different measurement conventions. The V1.5 specification for this part number states 3.7 ± 0.1 bar and 7600 ± 10% L/h. We will send the correct drawing and curve with your quotation.

Can it work at 12 V?

No. Rated voltage is 24 V and the permitted operating window is DC18–35 V. For 12 V systems, ask for the 12 V pump family.

Do you support OEM branding and custom brackets?

Yes. Logo, packaging, harness length and bracket geometry can be customised. Provide your mounting plate thickness and port orientation for a proposal.

Need a pump that will not derate in a hot, slow-moving vehicle? Send your voltage platform, required flow at working pressure, coolant temperature and installation space - we will confirm the 600W fan-cooled configuration and send the drawing with a quotation.

Contact now

 

Hot Tags: 600w fan-cooled electronic water pump, China, factory, suppliers, manufacturers, seller, wholesale, quotation

Send Inquiry

(0/10)

clearall