The role of the electronic water pump
The main application functions of automotive electronic water pumps in new energy vehicles As the name suggests, electronic water pumps are pumps with electronically controlled drive units. It mainly consists of three parts: overcurrent unit, motor unit and electronic control unit. With the help of the electronic control unit, the working state of the pump can be adjusted freely, such as: control the pump start/stop, flow control, pressure control, anti-dry running protection, self-maintenance and other functions, and can control the pump through external signals.
The magnet of the brushless DC centrifugal water pump is integrally formed with the impeller to form the magnetic rotor of the motor. In the center of the rotor there is a direct injection molded bushing. The shaft sleeve is high-resistance ground graphite fixed in the rotor body, and the motor stator and the circuit board pump body are filled with epoxy resin glue. There is a cavity between the stator and rotor. The cavity of the pump body is connected with the rotor cavity of the motor. The rotor chamber of the motor is completely isolated from the motor stator and motor controls. The shaft is made of high-smooth, high-strength zirconia. leakage.


The new energy vehicle cooling water pump is a mechanical device used to accelerate the flow cycle of vehicle coolant. However, the existing automotive cooling water pumps usually have complex structures, use many components, and have high production costs, and the existing automotive cooling water pumps have a large flow rate. The passing coolant contains a lot of impurities. If these impurities are not removed, it will affect the normal operation of the pump and shorten the service life of the pump. Conventional impellers on the market are usually made of metal materials, which are easily corroded and oxidized, easily damaged and have a short service life.
In order to ensure the normal use of electrical components of new energy vehicles, the inlet coolant temperature is not higher than 65°C, so the cooling circuit composed of radiators, electronic water pumps, motor controllers, and drive motor series is a low-temperature cooling cycle (relative to engine cooling circuit).


The main function of the electric water pump is to meet the technical requirements for thermal management of the drive motor, electric components, etc. under any working conditions of the vehicle. In new energy vehicles, the need for electric water pumps varies depending on the components to be cooled. Generally, the power requirement of electric water pumps for cooling drive motors and electrical components of passenger cars is usually below 150W, and electric water pumps driven by 12VDC motors can be used, and the water pumps can be in the form of canceling static and dynamic seals.