5kw Electric Heater Safety Inspection 1

Feb 14, 2023

5kw Electric Heater Safety Inspection 1

 

high voltage coolant heater

 

1. PCB temperature safety
Use the temperature sensor that comes with the MCU to detect the PCB temperature, and shut down and reduce power when the PCB is overheated. The protection logic is as follows:
When the PCB temperature is higher than 120°C, reduce the heating power according to the 80% derating factor, and restore the heating power when the temperature is lower than 115°C.
When the PCB temperature is higher than 125°C, stop heating, and resume heating when the temperature is lower than 110°C.

 

2. Media temperature safety
Two NTC temperature sensors are used to detect the temperature of the water inlet and outlet respectively. The MCU continuously detects the rationality of the temperature sensor signal. Once an abnormality is found, it will be identified as a temperature sensor failure, which can avoid the heating runaway event caused by the temperature sensor failure.
When the medium temperature is higher than 70°C, the heating is stopped, and when the medium temperature is lower than 60°C, the heating is resumed.


Note: The occurrence of this failure indicates that there may be a problem with the system, such as: the water pump failure causes the coolant flow to be interrupted, or there are air bubbles in the coolant system, or the coolant leaks, and a similar dry-burning condition occurs. Check and maintain the PTC electric heater in time, otherwise it may further lead to permanent failure of the PTC electric heater.

 

3.Current derating
When the PTC electric heater detects that the heating current is higher than 15A and the duration exceeds 3s, the current derating protection is performed, and the heating power is reduced according to the 80% derating factor.

 